欢迎来到上海颐品自动化科技有限公司!
全国服务咨询热线
13818772521
点击图片查看原图

Hawke非铠防爆格兰密封接头(501/421系列)

产品价格 面议

最小起订量:20 只 可售数量:500 只

用手机扫描二维码直达商品手机版
手机查看详情
发货时限:
30 天内发货
品牌:
Hawke
适用环境:
其他行业
安标证号:
无需办证
所在地区:
上海 金山区
有效期至:
长期有效
最后更新:
2024-02-21 10:41
浏览次数:
18844
产品详情
HAWKE 501/421 CABLE GLANDS   

HAWKE非铠防爆格兰(501/421系列)

 

HAWKE代理商:上海颐品自动化科技有限公司 

Hawke防爆格兰代理商:上海颐品自动化科技有限公司 

关键词:Hawke防爆格兰,Hawke防爆葛兰,Hawke防爆填料函,Hawke防爆密封接头

Hawke​非铠防爆格兰,Hawke铠装防爆格兰,Hawke防爆变径,Hawke防爆呼吸阀堵头

Hazardous Area Cable Glands from Hawke

Hawke防爆格兰(Hawke 501/421 cable glands ) 

Hawke 501/421 cable glands 适配非铠装电缆,

Hawke代理商:上海颐品自动化科技有限公司

Hawke 501/421 cable glands provide a reliable outer cable sheath seal specified to gland and terminate non-armoured elastomer and plastic insulated cables.

Hawke 501/421 cable glands are dual certified Exd and Exe and suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas, 3.2-91.6mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Non-Aromoured Cables ATEX & IECEx Cable Gland

Hawke 501/421 cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof Exdb

  • Increased Safety Exeb

  • Dust Extb

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/421 CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exed IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECtION TABLE FOR HAWKE 501/421

HAWKE 501/421 CABLE GLAND SELECTION TABLE
Hawke Size Ref. Entry Thread Size Thread Length ‘H’ Cable Acceptance Details ‘G’ Compressed Length Hexagon Dimensions
Outer Sheath ‘B’
Metric NPT * Standard Seal Alternative (S) Seal Across Flats Across Corners
Standard Option Min. Max. Min. Max.
2K M16 15.0 3.2 8.0 23.5 19.0 21.2
Os M20 ‡ ½” 15.0 3.2 8.0 23.8 24.0 26.5
O M20 ‡ ½” 15.0 6.5 11.9 23.8 24.0 26.5
A M20 ¾” ½” 15.0 10.0 14.3 9.0 13.4 24.8 30.0 32.5
B M25 1″ ¾” 15.0 13.0 20.2 9.5 15.4 25.8 36.0 39.5
C M32 1¼” 1″ 15.0 19.5 26.5 15.5 21.2 28.2 46.0 50.5
C2 M40 1½” 1¼” 15.0 25.0 32.5 22.0 28.0 29.5 55.0 60.6
D M50 2″ 1½” 15.0 31.5 44.4/42.3 † 27.5 34.8 40.4 65.0 70.8
E M63 2½” 2″ 15.0 42.5 56.3/54.3 † 39.0 46.5 38.2 80.0 88.0
F M75 3″ 2½” 15.0 54.5 68.2/65.3 † 49.5 58.3 40.5 95.0 104.0
G M80 3½” 20.0 67.0 73.0 41.0 106.4 115.0
H M90 3½” 20.0 67.0 77.6 41.0 115.0 130.0
J M100 4″ 20.0 75.0 91.6 41.0 127.0 142.0

All dimensions in millimetres (except*).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.

CABLE GLAND MATERIAL & FINISH

Hawke 501/421 cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/421
CABLE PREPARATION

Allow sufficient length of cable, measurement II, to suit the electrical equipment. If required, install cable gland shroud. Pass cable through the cable gland as shown. If the equipment has a threaded entry, Hawke recommend screwing the cable gland into the equipment to prevent cable twisting after Step B.

CABLE GLAND PREPARATION

Unless already screwed into the electrical equipment, hold the entry (2) in position with a cable gland spanner/wrench to prevent cable rotation and tighten the backnut (1) until resistance is felt between the cable and seal. Then proceed to turn the back nut through a further half to one full turn to complete the inner seal. Locate the shroud over the cable gland where required. To ease wiring inside the equipment strip the cable outer sheath of the cable as shown.

 Click Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

Hawke防爆格兰(Hawke Cable Gland)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格兰代理商:上海颐品自动化科技有限公司

关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,

Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱

Hawke防爆格兰等产品规格书及相关证书-请咨询上海颐品自动化科技有限公司

 

  
询价单

电话咨询

咨询电话:
13818772521

在线客服

微信客服

回到顶部